Abstract:
Controlled oil exposure study to evaluate the effects of south Louisiana crude oil chemically enhanced water accommodated fraction (CEWAF) exposure on Florida pompano and reproduction. Data include total polycyclic aromatic hydrocarbon (tPAH) results for exposure solutions, pompano livers, and pompano whole bodies, as well as volatile organic compound (VOC) results for exposure solutions.
Suggested Citation:
DL Wetzel, TA Sherwood, CA Miller, RL Medvecky. 2019. CEWAF-exposed Florida pompano reproduction: tPAH results. Distributed by: GRIIDC, Harte Research Institute, Texas A&M University–Corpus Christi. doi:10.7266/N7CF9NMN
Data Parameters and Units:
Tank Descriptions worksheet: Tank, # Female, # Male, Treatment, Start and End Dates (MM/DD/YYYY), Date Spike A (MM/DD/YYYY), Time Spike A, Date Spike B (MM/DD/YYYY), Time Spike B.
208 Sample Key worksheet: Collected date (MM/DD/YYYY), Collected Location (MAP - Mote Aquaculture Park), Field ID, Matrix, MML #, Species.
Stock CEWAF Preparation worksheet: Date (MM/DD/YYYY), Start Time, Carboy ID, Oil (g), Corexit (g), Seawater (L).
CEWAF Dilution Preparation worksheet: Date (MM/DD/YYYY), Time, Carboy ID, Stock Vol (L), Final Vol (L).
TPH_TANK H2O_Results worksheet: Sample, Tank, TPH (ug/L), Date (MM/DD/YYYY).
PAH_Tank_H2O Results worksheet: PAH Analyte, PAH units (ug/L), MDL (ug/L), MML, Treatment, Spike #, Tank, Sample Date (MM/DD/YYYY).
Liver PAH Results worksheet: PAH Analyte, PAH units (ug/L), MDL (ug/L), MML, Treatment, Fish ID, Comment, Sample Date (MM/DD/YYYY).
WHOLE BODY PAH Results worksheet: PAH Analyte, PAH units (ug/L), MDL (ug/L), MML, Treatment, Fish ID, Comment, Sample Date (MM/DD/YYYY).
VOC Results worksheet: Analyte, Concentration (ug/L), Qualifier.
Methods:
Tissue samples were surrogated with naphthalene d8, acenaphthene d10, phenanthrene-d10, chrysene-d12, perylene d12 and extracted via EPA method 3545 using a Dionex ASE300, then concentrated to 10ml in DCM for analysis. Water samples were surrogated with naphthalene d8, acenaphthene d10, phenanthrene-d10, chrysene-d12, perylene d12 and extracted via EPA method 3510, and concentrated to 1mL in DCM for analysis. PAHs were analyzed using gas chromatography/mass spectrometry in selected ion monitoring mode using a 0.25 um film thickness, 0.25 mm I.D., and 30 m length capillary column. One microliter of sample was injected at 60ºC, held for 1.5 minute. Temperature was then increased to 325 ºC at a rate of 8 ºC/ min, and held for 3 min. VOC samples were collected in accordance with Pace Analytical collection protocols, then sent to Pace Analytical for evaluation.