Oil Composition and nutrients for the GOMCOAST mesocosm using Gulf Of Mexico COASTal water
Funded By:
Gulf of Mexico Research Initiative
Funding Cycle:
RFP-IV
Research Group:
Aggregation and Degradation of Dispersants and Oil by Microbial Exopolymers (ADDOMEx)
Terry Wade
Texas A&M University / Geochemical and Environmental Research Group
terry@gerg.tamu.edu
oil composition, oil concentration, mesocosm, PAH, TPAH, n-alkanes, nutrients, polycyclic aromatic hydrocarbons, EOE, estimated oil equivalence
Abstract:
Mesocosm experiments were performed with Gulf of Mexico seawater collected from the Texas coastline, near TABS buoy R (29° 38.1000'N, 93° 38.5020'W) and was amended with nutrients. The four treatments in triplicate were analyzed for oil composition were 1) Control, 2) Water accommodated oil fraction (WAF), 3) Chemically enhanced (Corexit 9500) water accommodated fraction (CEWAF), and 4) 10-fold diluted CEWAF (DCWAF). The oil composition data presented here are EOE (estimated oil equivalence using fluorescence), PAH (polycyclic aromatic hydrocarbons), and Total PAH. Additionally, nutrients for these treatments are also included.
Suggested Citation:
Terry L. Wade, Anthony H. Knap, Dawei Shi, Gerardo Gold-Bouchot, Maya E. Morales-McDevitt, Stephen T. Sweet, Peter H. Santschi and Antonietta Quigg. 2019. Oil Composition and nutrients for the GOMCOAST mesocosm using Gulf Of Mexico COASTal water. Distributed by: GRIIDC, Harte Research Institute, Texas A&M University–Corpus Christi. doi:10.7266/N74X568X
Publications:
Purpose:
To determine the concentration of oil constituents and dispersant and their degradation with time in four different mesocosm treatments from coastal waters. Also, to track the change in nutrients during the same time course.
Data Parameters and Units:
nut-m4-griidc.csv: Time (hr); Sample; NO3- concentration (umol/L and mg/L N); HPO4 concentration (umol/L and mg/L P); HSiO3- concentration (umol/L and mg/L SiO3); NO2- concentration (umol/L and mg/L N); Urea concentration (umol/L and mg/L N); Nitrate+Nitrite concentration (mg/L N); SilCon= Silicone control, This has duplicates i.e. A and B. Collected at 0, 24, 48 and 72 hours; SilWAF= Silicone WAF, This has triplicates i.e. A, B and C. Collected at 0, 24, 48 and 72 hours; NO3- is nitrate; N is nitrogen; HPO4= is hydrogen phosphate; P is Phosphorus; HSIO3- is hydrogen silicate; SiO3 refers to silicate; NH4+ is ammonium; NO2- is nitrite, Total PAH M4 GRIIDC.csv: Treatment (Control, WAF, DCEWAF, or CEWAF); Sample; Time (hr); Volume (L); Total Polycyclic Aromatic Hydrocarbons-PAHs with Perylene (ng/L) PAH M4 GRIIDC.csv: Treatment (Control, WAF, DCEWAF, or CEWAF); Sample; Time (hr); Volume (L); Polycyclic aromatic hydrocarbons-PAHs (ng/L) n-alkanes M4 GRIIDC rev.csv: Client sample ID; Sample descriptor; GERG ID; SDG; Dry weight; Matrix; Calculation basis (dry or wet); QC Batch ID; Method; Individual alkanes (ug/L); Total resolved (ug/L); Total TPH (ug/L); Total UCM (ug/L) M4 EOE.csv: Time (hr); Estimated oil equivalence-EOE (mg/L); Treatment (O=WAF, DM=DCEWAF, or M=CEWAF); Tank (A, B, or C); LB-Light bottle; DB-Dark bottle WAF-Water Accommodated Fraction; CEWAF-Chemically Enhanced Water Accommodated Fraction; DCEWAF-Diluted Chemically Enhanced Water Accommodated Fraction; -999 = below detection limit
Methods:
Twelve 100L mesocosm tanks were filled with Gulf of Mexico seawater collected from the Texas coastline, near TABS buoy R (29° 38.1000'N, 93° 38.5020'W) which is located ~100 miles away from Galveston (TX). Four treatments were prepared in triplicate. Control tanks were filled with seawater. Water accommodated fraction (WAF) of oil was prepared by mixing 25 mL (5 ml ~ every 30 min for 2.5 hrs) of Macondo surrogate oil into 130 L of seawater. Mixing ended 24 hrs. after the initial oil addition (Knap et al. 1986; Wade et al. 2017in preparation). The WAF was then introduced into the WAF mesocosm tanks and filled to 87 L and mixed. From these WAF tanks 6 L was removed for other experiments and analyses (2 L dark/light, 4 L hydrocarbon analyses). In order to make chemically enhanced water accommodated fraction (CEWAF), Corexit was mixed with oil in a ratio of 1:20 and 25 mL of this mixture (5 ml every 30 min for 2.5 hrs) of surrogate oil plus Corexit was added to 130 L of seawater. Mixing ended 24 hrs after the initial oil addition. The CEWAF was then introduced into the CEWAF mesocosm tanks and filled to 96 L and mixed. From these CEWAF tanks 13 L was removed for other experiments and analyses (7 L for the DCEWAF mesocosms, 2 L dark/light, 4 L hydrocarbon analyses). Diluted CEWAF (DCEWAF) was prepared by mixing 9 L of CEWAF with 78 L of the original seawater for a total volume of 87 L. From these DCEWAF tanks 6 L was removed for other experiments and analyses (2 L dark/light, 4 L hydrocarbon analyses). To the water in the 12 mesocosms, nutrients were added (final concentration f/20) and the tanks stirred. Banks of lights were placed behind each of the glass mesocosm tanks and a 12:12 light/dark cycle employed. Sampling commenced and defined as time zero. The estimated oil equivalents (EOE) were determined using Macondo surrogate oil as the calibration standard (Wade et al. 2011) for the fluorescence analyses (Horiba Scientific Aqualog Fluorometer). The EOE mean concentration of the three mesocosms for the control, WAF, DCEWAF and CEWAF at the start of the experiments were 0 mg/L, 0.26 mg/L, 2.74 mg/L and 41.5 mg/L, respectively. The EOE mean concentration of the three mesocosms for the in the control, WAF, DCEWAF and CEWAF after 72 hours were 0 mg/L , 0.06 mg/L, 1.03. and 17.3 mg/L, respectively. Estimated Oil Equivalence (EOE) The estimated oil equivalents (EOE) were determined by fluorescence (Wade et al. 2011) using Macondo surrogate oil as a standard to produce calibration curves at 5 to 7 concentrations. Water samples (5 to 20 ml) were extracted with 5 ml of dichloromethane. An aliquot of the extract was placed in a cuvette for fluorescence analyses (Horiba Scientific Aqualog Fluorometer). The EOE were determined from the calibration curve (Wade et al. 2011). Samples with florescence responses that exceeded the calibration curve were diluted so that their florescence was within the calibration range. Samples were taken at the beginning and end of the experiment and at intervals in between and at the same time point as measurements of other parameters during the experiment. PAH (polycyclic aromatic hydrocarbons) and Total PAH extraction of the sample with dichloromethane. The samples are then purified using silica/alumina columns. analyzed. The analysis is performed with gas chromatography to separate the individual aromatic compounds and with a mass selective detector in the selected ion mode for identification and quantification. The parent PAH (e.g. naphthalene) and its alkylated homolog’s (e.g. C-1, C-2, C-3 and C-4) are also determined. These analyses can be used to distiguish between petroleum and combustion sources or a mixture of these sources. The individual PAH compounds and their alkylated homologs are reported.
Instruments:
EOE fluorescence analyses was carried out using a Horiba Scientific Aqualog Fluorometer. Total PAH were determined by gas chromatography (GC) with a flame ionization detector (GC/FID) and PAHs by GC with a mass selective detector [Short et al., 1996].
Provenance and Historical References:
This dataset was accepted on 2017-12-13 and was updated again on 2019-08-07 to add nutrient data. The newly added data is in the separate directory named "Revised Data".